Midea AC P4 error code

What it means

Compressor discharge temperature protection

Usual causes

  • Gas shortage / leak
  • Discharge sensor wiring wrong
  • Discharge sensor faulty
  • Outdoor main board fault

What you can safely try

  1. Switch the AC off at the switch or MCB.
  2. Wait 5 minutes, then switch on and start it with the remote.
  3. If P4 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
  • Is discharge temperature really above 115°C?
  • Check sensor wiring to PCB
  • Check for leaks
  • Measure discharge sensor. Discharge sensor T5 (Appendix 2): 54.9 kΩ at 25°C, 29.2k at 40°C, 19.7k at 50°C, 5 kΩ at 90°C

From the Midea service manual. These checks use meters and live power – for trained technicians only.

About this series: This model uses its own outdoor code list.