Midea AC error codes – Multi-split outdoor M5OA-36HRDN1-Q
Midea AC P2 error code
What it means
Low pressure protection
Usual causes
- LP switch wiring loose
- LP switch broken
- Outdoor temperature too low
- Refrigerant leak (pressure below 0.14 MPa)
- Blocked pipe
- Outdoor main board
What you can safely try
- Switch the AC off at the switch or MCB.
- Wait 5 minutes, then switch on and start it with the remote.
- If P2 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
- Check LP switch wiring
- Short the LP switch socket temporarily - if unit runs, switch is bad
- Gauge on service port: below 0.14 MPa = leak
From the Midea service manual. These checks use meters and live power – for trained technicians only.
About this series: This model uses its own outdoor code list.