Maheshwari HVAC Solutions

Midea AC P2 error code

What it means

Low pressure protection

Usual causes

  • LP switch wiring loose
  • LP switch broken
  • Outdoor temperature too low
  • Refrigerant leak (pressure below 0.14 MPa)
  • Blocked pipe
  • Outdoor main board

What you can safely try

  1. Switch the AC off at the switch or MCB.
  2. Wait 5 minutes, then switch on and start it with the remote.
  3. If P2 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
  • Check LP switch wiring
  • Short the LP switch socket temporarily - if unit runs, switch is bad
  • Gauge on service port: below 0.14 MPa = leak

From the Midea service manual. These checks use meters and live power – for trained technicians only.

About this series: This model uses its own outdoor code list.