Midea AC P3 error code

What it means

Compressor current protection

Usual causes

  • Input current too high (limits: 8.5 A small units, 15 A for 18-21K and 27K 1x3, 18.5 A 27K 1x4, 21.5 A 36K)
  • High outdoor temperature
  • Poor ventilation
  • Dirty condenser
  • Blocked pipe
  • Outdoor main board

What you can safely try

  1. Switch the AC off at the switch or MCB.
  2. Wait 5 minutes, then switch on and start it with the remote.
  3. If P3 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
  • Clamp the supply current
  • Check refrigerant system, site temperature, airflow, condenser

From the Midea service manual. These checks use meters and live power – for trained technicians only.

About this series: This model uses its own outdoor code list.