Samsung AC E464 error code

What it means

IPM over current (O.C) error

Usual causes

  • IPM shunt resistor open
  • Abnormal overload condition
  • Sensor detached or wrong reading
  • Compressor winding fault / wires loose

What you can safely try

  1. Switch the AC off at the switch or MCB.
  2. Wait 5 minutes, then switch on and start it with the remote.
  3. If E464 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
  • Check compressor wire connections
  • Check site load (indoor/outdoor temperature)
  • Check sensor position and values
  • Check compressor winding resistance and insulation

From the Samsung service manual. These checks use meters and live power – for trained technicians only.

About this series: Indoor shows the code on the 7-segment display. Outdoor PBA has 3 LEDs: YEL, GRN, RED (on / off / blinking). Normal outdoor display: RED on, GRN blinking, YEL off.