Samsung AC error codes – Inverter split AR09/12/18/24HSF
Samsung AC E464 error code
What it means
IPM over current (O.C) error
Usual causes
- IPM shunt resistor open
- Abnormal overload condition
- Sensor detached or wrong reading
- Compressor winding fault / wires loose
What you can safely try
- Switch the AC off at the switch or MCB.
- Wait 5 minutes, then switch on and start it with the remote.
- If E464 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
- Check compressor wire connections
- Check site load (indoor/outdoor temperature)
- Check sensor position and values
- Check compressor winding resistance and insulation
From the Samsung service manual. These checks use meters and live power – for trained technicians only.
About this series: Indoor shows the code on the 7-segment display. Outdoor PBA has 3 LEDs: YEL, GRN, RED (on / off / blinking). Normal outdoor display: RED on, GRN blinking, YEL off.