Samsung AC error codes – Inverter split AR09/12/18/24HSF
Samsung AC E422 error code
What it means
EEV or service valve closed (self-diagnosis)
Usual causes
- Service valve not fully open
- EEV coil unplugged (CN701) or EEV stuck
- Gas leak / low charge
- Indoor Eva-in sensor out of position
What you can safely try
- Switch the AC off at the switch or MCB.
- Wait 5 minutes, then switch on and start it with the remote.
- If E422 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
- Check indoor Eva-in sensor position
- Restart after 20 min
- Listen for EEV clicking at power on, check CN701
- Check refrigerant pressure
From the Samsung service manual. These checks use meters and live power – for trained technicians only.
About this series: Indoor shows the code on the 7-segment display. Outdoor PBA has 3 LEDs: YEL, GRN, RED (on / off / blinking). Normal outdoor display: RED on, GRN blinking, YEL off.