Samsung AC E466 error code

What it means

DC-link voltage under / over

Usual causes

  • Supply voltage outside 180-270 V AC
  • Reactor wire loose
  • DC-link capacitor or sensing resistor fault on outdoor PBA

What you can safely try

  1. Switch the AC off at the switch or MCB.
  2. Wait 5 minutes, then switch on and start it with the remote.
  3. If E466 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
  • Input voltage at power cord 180-270 V AC
  • DC-link voltage in operation 280-320 V DC
  • DC-link sensing voltage 0.2-4.0 V DC
  • Reactor insulation

From the Samsung service manual. These checks use meters and live power – for trained technicians only.

About this series: Indoor shows the code on the 7-segment display. Outdoor PBA has 3 LEDs: YEL, GRN, RED (on / off / blinking). Normal outdoor display: RED on, GRN blinking, YEL off.