Maheshwari HVAC Solutions

Samsung AC E462 error code

What it means

AC input current limit trip (PFC over current)

Usual causes

  • Overload - very hot outdoor, dirty coils
  • Temperature sensor out of place giving wrong reading
  • PFC shunt resistor open (R410-R412 / R408-R410)
  • Compressor cable / power terminal loose

What you can safely try

  1. Switch the AC off at the switch or MCB.
  2. Wait 5 minutes, then switch on and start it with the remote.
  3. If E462 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
  • Check site load conditions
  • Check sensor positions and values
  • Check compressor and power terminal connections

From the Samsung service manual. These checks use meters and live power – for trained technicians only.

About this series: Indoor shows the code on the 7-segment display. Outdoor PBA has 3 LEDs: YEL, GRN, RED (on / off / blinking). Normal outdoor display: RED on, GRN blinking, YEL off.