Samsung AC error codes – Inverter split AR09/12/18/24HSF
Samsung AC E462 error code
What it means
AC input current limit trip (PFC over current)
Usual causes
- Overload - very hot outdoor, dirty coils
- Temperature sensor out of place giving wrong reading
- PFC shunt resistor open (R410-R412 / R408-R410)
- Compressor cable / power terminal loose
What you can safely try
- Switch the AC off at the switch or MCB.
- Wait 5 minutes, then switch on and start it with the remote.
- If E462 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
- Check site load conditions
- Check sensor positions and values
- Check compressor and power terminal connections
From the Samsung service manual. These checks use meters and live power – for trained technicians only.
About this series: Indoor shows the code on the 7-segment display. Outdoor PBA has 3 LEDs: YEL, GRN, RED (on / off / blinking). Normal outdoor display: RED on, GRN blinking, YEL off.