Midea AC error codes – Multi-split outdoor M2/M3/M4 OC - outdoor digital tube
Midea AC E7 error code
What it means
Communication fault between IPM board and outdoor main board
Usual causes
- IPM-to-main-board cable loose
- IPM board fault
- Outdoor main PCB fault
What you can safely try
- Switch the AC off at the switch or MCB.
- Wait 5 minutes, then switch on and start it with the remote.
- If E7 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
- Check IPM board for its own error display
- Re-seat connecting cable
From the Midea service manual. These checks use meters and live power – for trained technicians only.
About this series: Outdoor LED shows "--" standby, running frequency when running, "dF" in defrost. Press SW1 to step through check data (1 demand, 2 mode, 4 fan, 5-8 coil outlet temps, 9 condenser, 10 ambient, 11 discharge, 12 inverter current).