Maheshwari HVAC Solutions

LG AC 7 error code

What it means

Over-current (CT2)

Also shown as CH07 (models with digital display)

Usual causes

  • Bad supply, indoor/outdoor fan locked, overcharge, current-sensing circuit fault. Set when current reaches I2 5× in 1 h.

What you can safely try

  1. Switch the AC off at the switch or MCB.
  2. Wait 5 minutes, then switch on and start it with the remote.
  3. If 7 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
  • Supply voltage
  • both fans run
  • refrigerant pressure. CT wire, BD01N orientation, R01N 1 kΩ, R02N 1.65 kΩ, D01N/D02N direction. I2 = 9 A (9K), 10 A (12K), 13 A (18K).

From the LG service manual. These checks use meters and live power – for trained technicians only.

About this series: Error code = number of blinks of the indoor operation LED (and red LED01M on outdoor PCB), repeated every 3 s. Codes 1,2,4,10 clear when fixed; 5,8,9 stay until restart; 6,7 need power reset.