LG AC error codes – Inverter split AS-W0964/1264/1865DH0 & GH0, AS-W1224/1424/1825DH0
LG AC 6 error code
What it means
DC peak error (IPM over-current / compressor lock)
Also shown as CH06 (models with digital display)
Usual causes
- Bad supply, CN-U/V/W loose or swapped, compressor coil short, overcharge, outdoor PCB/IPM faulty. Also set if DC link < 140 V 5× in 1 h, or outdoor pipe > 65°C (fan lock) 5× in 1 h. IPM trip at 35 A ±3 A.
What you can safely try
- Switch the AC off at the switch or MCB.
- Wait 5 minutes, then switch on and start it with the remote.
- If 6 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
- Supply ~AC 220/240 V. CN-U RD, V BL, W YL. Compressor U-V, V-W, U-W 1-2 Ω, to body > 10 MΩ. Check SPM pins (GND-P,U,V,W) for short, DC 15 V output of power module, IPM screws.
From the LG service manual. These checks use meters and live power – for trained technicians only.
About this series: Error code = number of blinks of the indoor operation LED (and red LED01M on outdoor PCB), repeated every 3 s. Codes 1,2,4,10 clear when fixed; 5,8,9 stay until restart; 6,7 need power reset.