Maheshwari HVAC Solutions

LG AC 1 error code

What it means

Indoor room/pipe sensor open or short

Also shown as CH01 (models with digital display)

Usual causes

  • Sensor open/short, not connected to indoor PCB, sensing circuit fault (R01H-R04H, C01H, C02H)

What you can safely try

  1. Switch the AC off at the switch or MCB.
  2. Wait 5 minutes, then switch on and start it with the remote.
  3. If 1 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
  • Unplug and measure: air sensor ~10 kΩ at 25°C, pipe sensor ~5 kΩ at 25°C. Check it is plugged into CN-TH1 and the sensing resistors/capacitors on the PCB.

From the LG service manual. These checks use meters and live power – for trained technicians only.

About this series: Error code = number of blinks of the indoor operation LED (and red LED01M on outdoor PCB), repeated every 3 s. Codes 1,2,4,10 clear when fixed; 5,8,9 stay until restart; 6,7 need power reset.