Maheshwari HVAC Solutions

Samsung AC E251 error code

What it means

Discharge temperature sensor error

Usual causes

  • CN251 loose
  • Sensor open/short
  • Outdoor PBA faulty

What you can safely try

  1. Switch the AC off at the switch or MCB.
  2. Wait 5 minutes, then switch on and start it with the remote.
  3. If E251 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
  • Measure CN251 #3-#4: 200 kΩ ±3% at 25°C (20°C 242k, 30°C 166k, 35°C 138k, 40°C 115k)
  • Power on: below 0.5 V or above 4.5 V = PBA fault

From the Samsung service manual. These checks use meters and live power – for trained technicians only.

About this series: Indoor shows the code on the 7-segment display. Outdoor PBA has 3 LEDs: YEL, GRN, RED (on / off / blinking). Normal outdoor display: RED on, GRN blinking, YEL off.