Maheshwari HVAC Solutions

Samsung AC E122 error code

What it means

Indoor coil sensor error (Eva-MID / Eva-IN pipe sensor)

Also shown as E123

Usual causes

  • Sensor connector loose or sensor out of its pipe holder
  • Sensor open/short
  • Indoor PBA faulty

What you can safely try

  1. Switch the AC off at the switch or MCB.
  2. Wait 5 minutes, then switch on and start it with the remote.
  3. If E122 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
  • Measure sensor pins #3-#4 and #5-#6: 10 kΩ ±3% at 25°C (20°C 12.09k, 30°C 8.31k)
  • Power on: pin voltage below 0.5 V or above 4.5 V = PBA fault

From the Samsung service manual. These checks use meters and live power – for trained technicians only.

About this series: Indoor shows the code on the 7-segment display. Outdoor PBA has 3 LEDs: YEL, GRN, RED (on / off / blinking). Normal outdoor display: RED on, GRN blinking, YEL off.