Samsung AC error codes – Inverter split AR09/12/18/24HSF
Samsung AC E121 error code
What it means
Indoor room temperature sensor error
Usual causes
- Sensor connector loose
- Sensor open/short (resistance out of range)
- Indoor PBA faulty
What you can safely try
- Switch the AC off at the switch or MCB.
- Wait 5 minutes, then switch on and start it with the remote.
- If E121 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
- Unplug sensor from PBA and measure: 10 kΩ ±3% at 25°C (20°C 12.09k, 30°C 8.31k, 35°C 6.94k, 40°C 5.83k)
- Refit sensor, power on and measure voltage at connector pins #1-#2: below 0.5 V or above 4.5 V means PBA problem
From the Samsung service manual. These checks use meters and live power – for trained technicians only.
About this series: Indoor shows the code on the 7-segment display. Outdoor PBA has 3 LEDs: YEL, GRN, RED (on / off / blinking). Normal outdoor display: RED on, GRN blinking, YEL off.