Maheshwari HVAC Solutions

Samsung AC E121 error code

What it means

Indoor room temperature sensor error

Usual causes

  • Sensor connector loose
  • Sensor open/short (resistance out of range)
  • Indoor PBA faulty

What you can safely try

  1. Switch the AC off at the switch or MCB.
  2. Wait 5 minutes, then switch on and start it with the remote.
  3. If E121 comes back, note it and call us. Please don’t open the panels, touch wiring or handle gas.
What our technician checks
  • Unplug sensor from PBA and measure: 10 kΩ ±3% at 25°C (20°C 12.09k, 30°C 8.31k, 35°C 6.94k, 40°C 5.83k)
  • Refit sensor, power on and measure voltage at connector pins #1-#2: below 0.5 V or above 4.5 V means PBA problem

From the Samsung service manual. These checks use meters and live power – for trained technicians only.

About this series: Indoor shows the code on the 7-segment display. Outdoor PBA has 3 LEDs: YEL, GRN, RED (on / off / blinking). Normal outdoor display: RED on, GRN blinking, YEL off.