Haier AC error codes – Split AC

31 codes from the Haier service manual, with what each one means and the usual causes. Checks are standard practice.

You can safely switch the unit off at the switch, wait 5 minutes and switch on again. Don't open the unit, touch wiring or handle gas: these checks need a trained technician.

E1

Indoor room sensor failure

What our technician checks
  • Room (return air) sensor: unplug and measure - most split ACs use 10 kΩ at 25°C (about 12.6 kΩ at 20°C, 8 kΩ at 30°C). Open or short = faulty. Check connector on the indoor PCB.
Book a technician for E1

E2

Indoor pipe sensor failure

What our technician checks
  • Indoor coil (pipe) sensor: unplug and measure (commonly 10 kΩ or 5 kΩ at 25°C depending on brand). Check it is clipped into the coil sensor pocket.
Book a technician for E2

E4

Indoor EEPROM failure

What our technician checks
  • Power off 3 min and restart.
Book a technician for E4

E5

Indoor anti-freeze protection

What our technician checks
  • Indoor filter / coil dirty, blower slow, low gas, very low set temperature with low indoor load.
Book a technician for E5

E7

Indoor-outdoor communication fault

What our technician checks
  • Interconnect cable: correct terminal order (L, N, signal, earth), no loose screw or joint, cable not run with other power cables. Is the outdoor unit powered (LED on outdoor PCB)? Signal line voltage fluctuates when healthy. Check outdoor fuse and reactor.
Book a technician for E7

E9

Indoor overload in heating

What our technician checks
  • Condenser dirty or air recirculating, outdoor fan slow, overcharge, air / nitrogen in system, valves closed (heating: indoor filter / fan).
Book a technician for E9

E14

Indoor fan motor fault

What our technician checks
  • Indoor blower turns freely by hand? Blower wheel clean, not rubbing? Fan motor connector, motor supply (AC: capacitor
  • DC: about 310 V DC + 15 V and feedback signal).
Book a technician for E14

F1

IPM protection

What our technician checks
  • Power off, wait for capacitors to discharge. Compressor U-V, V-W, W-U equal (about 0.5-3 Ω) and >10 MΩ to earth. Diode test the IPM P/N to U/V/W. Check DC bus (about 310 V DC on 230 V supply), heat-sink paste and screws, condenser cleanliness, supply voltage, overcharge.
Book a technician for F1

F2

Compressor instant over-current

What our technician checks
  • Supply voltage under load, condenser dirty or outdoor fan slow, overcharge, air in system, compressor current against rated.
Book a technician for F2

F3

Communication between power module and main PCB

What our technician checks
  • Interconnect cable: correct terminal order (L, N, signal, earth), no loose screw or joint, cable not run with other power cables. Is the outdoor unit powered (LED on outdoor PCB)? Signal line voltage fluctuates when healthy. Check outdoor fuse and reactor.
Book a technician for F3

F4

Discharge temperature protection

What our technician checks
  • Low refrigerant charge (most common), blocked expansion valve / capillary, EEV not opening, discharge sensor reading wrong.
Book a technician for F4

F6

Outdoor ambient sensor failure

What our technician checks
  • Outdoor sensor (ambient / coil / suction): unplug and measure against the brand chart (outdoor ones are usually 10 kΩ, discharge sensors 50-200 kΩ at 25°C).
Book a technician for F6

F7

Suction temperature sensor failure

What our technician checks
  • Outdoor sensor (ambient / coil / suction): unplug and measure against the brand chart (outdoor ones are usually 10 kΩ, discharge sensors 50-200 kΩ at 25°C).
Book a technician for F7

F8

Outdoor DC fan motor fault

What our technician checks
  • Outdoor fan turns freely (bearing)? Leaves / debris? DC fan: motor supply from the outdoor PCB and feedback wire.
Book a technician for F8

F9

Module reset (supply dip)

What our technician checks
  • Measure mains under load (single phase normally 200-250 V). Loose neutral, undersized cable, stabiliser.
Book a technician for F9

F11

Compressor loss of synchronism

What our technician checks
  • Compressor windings equal and not earthed? U/V/W lead order and connection. Refrigerant pressures equalised before start? Board output to compressor.
Book a technician for F11

F12

Outdoor EEPROM failure

What our technician checks
  • Power off 3 min and restart.
Book a technician for F12

F13

Lack of refrigerant

What our technician checks
  • Suction pressure low? Leak test (flare joints, valves, coils) with soap / nitrogen. Valves fully open?
Book a technician for F13

F14

4-way valve reversing failure

What our technician checks
  • 4-way valve coil voltage and resistance
  • valve sticking (heating models).
Book a technician for F14

F19

Supply over / under voltage

What our technician checks
  • Measure mains under load (single phase normally 200-250 V). Loose neutral, undersized cable, stabiliser.
Book a technician for F19

F20

High pressure protection

What our technician checks
  • Condenser dirty or air recirculating, outdoor fan slow, overcharge, air / nitrogen in system, valves closed (heating: indoor filter / fan).
Book a technician for F20

F21

Outdoor coil sensor fault

What our technician checks
  • Outdoor sensor (ambient / coil / suction): unplug and measure against the brand chart (outdoor ones are usually 10 kΩ, discharge sensors 50-200 kΩ at 25°C).
Book a technician for F21

F22

Outdoor AC over-current

What our technician checks
  • Supply voltage under load, condenser dirty or outdoor fan slow, overcharge, air in system, compressor current against rated.
Book a technician for F22

F23

Compressor U/V/W phase over-current

What our technician checks
  • Power off, wait for capacitors to discharge. Compressor U-V, V-W, W-U equal (about 0.5-3 Ω) and >10 MΩ to earth. Diode test the IPM P/N to U/V/W. Check DC bus (about 310 V DC on 230 V supply), heat-sink paste and screws, condenser cleanliness, supply voltage, overcharge.
Book a technician for F23

F24

CT current detection abnormal

What our technician checks
  • Current sensing circuit on the outdoor board.
Book a technician for F24

F25

Discharge sensor abnormal

What our technician checks
  • Discharge pipe sensor: measure (typically 50-200 kΩ at 25°C, brand dependent) and check it is fixed on the discharge pipe.
Book a technician for F25

F27

Compressor current sampling circuit fault

What our technician checks
  • Current sensing circuit on the outdoor board.
Book a technician for F27

F28

Compressor position detection circuit fault

What our technician checks
  • Compressor leads and windings
  • board drive section.
Book a technician for F28

F35

Compressor driver board failure

What our technician checks
  • Power off, wait for capacitors to discharge. Compressor U-V, V-W, W-U equal (about 0.5-3 Ω) and >10 MΩ to earth. Diode test the IPM P/N to U/V/W. Check DC bus (about 310 V DC on 230 V supply), heat-sink paste and screws, condenser cleanliness, supply voltage, overcharge.
Book a technician for F35

F43

Model matching abnormality

What our technician checks
  • Indoor and outdoor model numbers are a matching pair? Correct capacity / model setting on the board.
Book a technician for F43

FE

Refrigerant leak detected (fixed speed)

What our technician checks
  • Suction pressure low? Leak test (flare joints, valves, coils) with soap / nitrogen. Valves fully open?
Book a technician for FE

Code not here, or still showing?

Send a photo of the display and the model sticker on WhatsApp. We'll tell you what it means and whether it needs a visit.